Type each core's weight, height, diameter and load, or leave the sheet empty to print a blank format. H/D ratio, density, correction factor (f = 0.11 U + 0.78 for U < 2), corrected load, area, crushing strength and equivalent cube strength (1.25 × corrected crushing strength) are worked out as you type. Enter fck to get the required strength (85% of fck). Typed values are saved for this project.
CH: |
PQC CORE CRUSHING STRENGTH | |||||||||||||
| Core No. | Location | Weight (gm) | Height (MM) | Dia (MM) | Height/ Diameter Ratio (U) | Density (gm/cc) | LOAD (KN) | CORRECTION FACTOR AS PER MORT&H (f = 0.11 U + 0.78) | CORRECTED LOAD (KN) | AREA (MM²) | CRUSHING STRENGTH (N/mm²) | Equivalent Cube strength of concrete (Corrected Crushing Strength × 1.25) | Crushing Strength required (N/mm²) as per MORT&H (85% of Compressive Strength) | Remarks |
| Remarks : | ||||||||||||||
|
Name:
Date:
Contractor's Representative
|
Name:
Date:
Concessionaire's/PMC Representative
|
Name:
Date:
IE's Representative
|