← Hume Pipes

Physical Measurements of RCC Hume Pipes

Format · IS:458-2003 · dimensions and tolerances

Fill in the pipe details and the measured dimensions, or leave the sheet empty to print a blank format. The IS 458 tolerances are printed below the table. Typed values are saved for this project.

PHYSICAL MEASUREMENTS OF RCC HUME PIPES
[As per IS:458 -2003]
Concrete Pipes Class:
Source/Location:
Dia of Pipes:
No of pipes:
Lot No:
Sl.NOREF. PIPE NOINTERNAL DIAMETER (mm)LENGTH (mm) WALL THICKNESS (mm)DEVIATION FROM STRAIGHT (mm)REMARKS
Tolerances as per IS 458 - 2003 :
1. Overall length: ± 1% of standard length
2. Internal diameter: ± 10 mm
3. Wall thickness: + 7mm
  - 3.5 mm
4. Deviation from straight: < 3 mm for every metre run
Remarks :
Name:
Date:
Contractor's Representative
Name:
Date:
Concessionaire's/PMC Representative
Name:
Date:
IE's Representative