← Micro-Surfacing

Micro-Surfacing Mix Design

Type II / Type III · MoRT&H Section 500 (Tables 500-26 to 500-33) / IRC:SP:81

1. Design details

These feed the front page of the Design Report. Tick fibre and / or additive when the design uses them — their rows then appear in the trial mixes, the Job Mix Formula and the quantities.

2. Polymer modified emulsion (Annexure I)

MoRT&H Table 500-32. Type the test results; the remark is worked out. The residue by evaporation is used for the residual binder in section 5.

S.N.Test parameterSpecificationTest methodResultRemark

3. Physical properties of aggregate (Annexure II)

S.N.Test parameterSpecificationTest methodResultRemark

Water absorption more than 2% but less than 4% may be permitted subject to the soundness test and the wet stripping test (MoRT&H Table 500-26).

4. Gradation & blending (Annexure III)

Enter the sieve analysis of each material in the Individual Gradation — Calculator on the right (screen 2). Their average % passing comes here; the blend gives the combined gradation, checked against MoRT&H Table 500-27 for the type chosen.

Individual Gradation — Summary

Blend & combined gradation

5. Trial hand mixes & Job Mix Formula

Proportions by weight of dry aggregate. Residual binder = emulsion % × residue % (section 2), as IRC:SP:81. Results are checked against MoRT&H Table 500-33 and Table 500-31.

DescriptionSpecificationHand Mix 1Hand Mix 2Hand Mix 3

6. Job quantities (from the JMF)

7. Report

Everything is saved for the active project in this browser (and synced when you are signed in). Logos and project details come from the main Projects page.

Individual Gradation — Calculator

Pick a material with Sieve data, then enter each sample: gross weight and moisture loss give the net dry weight, and the weight retained on each sieve gives % passing. + Add sample for another sample.

Reference

Click a heading to expand.

Aggregate grading (MoRT&H Table 500-27)
Sieve (mm)Type IIType IIITolerance (500-28)
Type & rate (MoRT&H Table 500-31)
Type II (4–6 mm)Type III (6–8 mm)
UseRoads < 1500 CVPD1500 – 4500 CVPD
Quantity of mix* (kg/m²)8.4 – 10.811.1 – 16.3
Residual binder (% of dry aggregate)6.5 – 10.55.5 – 10.5

* By weight of dry aggregate. Indicative only.

Other limits
Mineral filler (cement)0.5 – 2% of dry aggregate
Glass fibre (AR), if used0.2 – 0.3% of aggregate
WaterPotable, pH 6 – 7
LayingNot below 10 °C (air or pavement)
TrafficAfter about 2 h; 20–40 km/h at first

From MoRT&H Section 500 and IRC:SP:81 as used in the project methodology — verify against the contract specification.