1. Design details
These feed the front page of the Design Report. Tick fibre and / or additive when the design uses them — their rows then appear in the trial mixes, the Job Mix Formula and the quantities.
2. Polymer modified emulsion (Annexure I)
MoRT&H Table 500-32. Type the test results; the remark is worked out. The residue by evaporation is used for the residual binder in section 5.
| S.N. | Test parameter | Specification | Test method | Result | Remark |
|---|
3. Physical properties of aggregate (Annexure II)
| S.N. | Test parameter | Specification | Test method | Result | Remark |
|---|
Water absorption more than 2% but less than 4% may be permitted subject to the soundness test and the wet stripping test (MoRT&H Table 500-26).
4. Gradation & blending (Annexure III)
Enter the sieve analysis of each material in the Individual Gradation — Calculator on the right (screen 2). Their average % passing comes here; the blend gives the combined gradation, checked against MoRT&H Table 500-27 for the type chosen.
Individual Gradation — Summary
Blend & combined gradation
5. Trial hand mixes & Job Mix Formula
Proportions by weight of dry aggregate. Residual binder = emulsion % × residue % (section 2), as IRC:SP:81. Results are checked against MoRT&H Table 500-33 and Table 500-31.
| Description | Specification | Hand Mix 1 | Hand Mix 2 | Hand Mix 3 |
|---|
6. Job quantities (from the JMF)
7. Report
Everything is saved for the active project in this browser (and synced when you are signed in). Logos and project details come from the main Projects page.
Individual Gradation — Calculator
Pick a material with Sieve data, then enter each sample: gross weight and moisture loss give the net dry weight, and the weight retained on each sieve gives % passing. + Add sample for another sample.
Reference
Click a heading to expand.
Aggregate grading (MoRT&H Table 500-27)
| Sieve (mm) | Type II | Type III | Tolerance (500-28) |
|---|
Type & rate (MoRT&H Table 500-31)
| Type II (4–6 mm) | Type III (6–8 mm) | |
|---|---|---|
| Use | Roads < 1500 CVPD | 1500 – 4500 CVPD |
| Quantity of mix* (kg/m²) | 8.4 – 10.8 | 11.1 – 16.3 |
| Residual binder (% of dry aggregate) | 6.5 – 10.5 | 5.5 – 10.5 |
* By weight of dry aggregate. Indicative only.
Other limits
| Mineral filler (cement) | 0.5 – 2% of dry aggregate |
| Glass fibre (AR), if used | 0.2 – 0.3% of aggregate |
| Water | Potable, pH 6 – 7 |
| Laying | Not below 10 °C (air or pavement) |
| Traffic | After about 2 h; 20–40 km/h at first |
From MoRT&H Section 500 and IRC:SP:81 as used in the project methodology — verify against the contract specification.