← Material Testing System

Fineness — Blaine's Air Permeability

IS 4031 (Part 2):1999

⌂ Home

1. Sample details

2. Test data

3. Result

Specific surface, S —
Conformity —

S (m²/kg) = [521.08 × K × √T] / ρ / 10

Back-calculation — expected T2 for a target permeability time

Given T1 and the average permeability time you're targeting, solves for the T2 reading that would produce it.

4. Report

This app saves everything (test data) for the active project in your browser, tied to this folder.